Electrical connections are then securely made via clearly marked screw-down cage clamping terminal strip connections. As an Event input, support is provided for switched inputs such as contact closures, open collector transistors, reed switches, etc. The D-cells will power the unit for up to 3 months and can readily be user replaced. External Power — terminal strip connections are provided for direct connection of an external low-voltage DC source nominal Vdc. Signal Inputs Analog Inputs: As a substitute for one or both of the Digital Outputs, up to two relay outputs can be provided. Easy access front panel buttons behind the protective clear door provide user control for Enable, Stop and Reset of the unit.

Uploader: Gar
Date Added: 23 October 2005
File Size: 47.23 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 9916
Price: Free* [*Free Regsitration Required]

With the WP option, the IntelliLogger power supply has additional suppression and regulation circuitry allowing it to withstand up to 60Vdc continually and voltage spikes as commonly found on vehicle power busses. Additionally, the compressor cylinder head temperature is logged for baseline reference and cooling assessment.

The ABS and polycarbonate enclosure features a silicone gasketed clear door with secure latch, optional wall or surface mounting hanger. Compatibility with HyperWare-II results in a level of data logging and alarming flexibility never before available in such a low-cost instrument. As an Event input, support is provided for switched inputs such as contact closures, open collector transistors, reed switches, etc.

Example Heat Transfer Program Fig 3: Many transducers and transmitters such as ma loop powered devices require a power source. The IntelliLogger IL-Mini is an extremely versatile stand-alone data logging and alarming instrument… offered at a very cost competitive price point. Unique pressure equalizing venting is integral to the enclosure to protect it from ambient pressure changes as experienced during flights, shipment or elevation changes.

  ALC880 XP DRIVER

Ranges are selected via the HyperWare-II software and input types are selected via DIP switches on a channel by channel basis… allowing for mixing of mAdc, Vdc, and thermocouple to meet the application requirements… all on a single unit! Additionally, the Event input is commonly used to trigger conditional logging within a Program Net … for example, log only when the engine is on or log only when the brakes are applied.

Modbus – Device information

Sensor and signal wiring is via provided gland fittings and internal terminal strip connections. From these two pressures, a differential pressure across the dryer is calculated and logged and the output pressure is logged. If the optional LCD display is ordered, users can view real-time readings of channel as well as calculated values eg totalsstatus messages, custom alarm and status messages, remaining memory, battery state of charge and much more.

Blinking or steady ON modes are selectable. The historical compromise of flexibility vs cost in low-cost data logging platforms is now history. Internal Battery — with the DBatt option, 6 alkaline D-cells are provided in a slightly taller enclosure. The output flow 5 minute Min, max and average is The coolant flow transducer outputs a frequency that is a function of the flow rate. External Power — terminal strip connections are provided for direct connection of an external low-voltage DC source nominal Vdc.

Simultaneously it processes any user programmed alarm strategies and outputs accordingly. Example Heat Exchanger Program Fig 1: As a substitute for one or both of the Digital Outputs, up to two relay outputs can be provided. As D-cells are readily available all over the world, gone are the hassles associated with procuring and replacing specialty batteries or shipping the data logger back to the factory for a simple battery replacement!.

  MINOLTA QMS 2300DL PRINTER DRIVER

An energy consumption profile is developed based on energy consumed and is logged on 15 minute utility intervals. Easy access front panel buttons behind the protective clear door provide user control for Enable, Stop and Reset of the unit. Be the first to review!

Signal Inputs Analog Inputs: A lntellilogger mounting hanger allows for secure attachment of the unit to a wall or flat surface.

Packaged in a gasketed door, rugged weatherproof e Overprotection circuitry allows for up to 30VDc direct connection. The D-cells will power the unit for up to 3 months and can readily be user replaced.

Logic Beach Inc

Electrical connections are then securely made via clearly marked screw-down cage clamping terminal strip connections. Wind speed, water flow, kW consumption, and events are easily logged.

Next and Select buttons are provided with the LCD option to step through the multitude of display features. Each output has an optional LED indicator which can be ueb enabled for status when battery power consumption is not a concern.